INI settings that are used by eManifest

The TTS50.ini file contains the global settings that control how TMWSuite operates. You must set up this file for your company’s way of doing business. General information about the INI settings can be found in the TMWSuite System Administration Guide.

Brackets enclose all the section headings in your TTS50. Each setting must remain in its section. The TTS50 is not alphabetical - you must use your text editor’s Find tool to locate a setting or section.

In each section, settings are listed in alphabetical order. Clicking on a setting displays it in a new browser tab.

[Directories] settings

These settings used by eManifest are located in the [Directories] section of your TTS50.

[Directories]Bitmaps

Applies to

TMWSuite, CRM Right, TMW eManifest, TMW Operations, TMW Back Office

Description

This setting identifies the directory holding the TMWSuite bitmaps not supplied as part of the executables, such as, the logo displayed on the Login dialog box.

Note: The actual bitmap image used by the Login dialog box is specified by the [Misc]Logo setting in your TTS50.

Options

  • .\ (default)

    In the directory that contains the executable being launched, look for the image file that is specified by the [Misc]Logo setting in your TTS50.

  • Directory path
    Enter the path to the directory that contains the image file specified by the [Misc]Logo setting in your TTS50.

    For example, C:\IMAGES.

Additional Notes

  1. To display an alternate image in the Login dialog box, you must make a valid entry in both the Logo setting and the Bitmaps setting. If a valid entry is not made in both settings:

    • TMWSuite core applications will display a blank pane (no image).

    • CRM Right, TMW Operations, and TMW Back Office will display the default TMWSuite logo.

  2. Fuel TMS does not support this setting.

[Dispatch] settings

These settings used by eManifest are located in the [Dispatch] section of your TTS50.

[Dispatch]skipappclosequery

Applies to

TMWSuite V.2003 and later, Fuel Dispatch, Inventory Services, TMW eManifest, TMW Operations, TMW Back Office

Description

This setting determines whether, when users close an application, the system will display a message asking them to confirm their intent to exit.

Options

  • No (default)
    Display the confirmation message.

  • Yes
    Do not display the confirmation message.

Additional Notes

CRM Right does not support this setting.

[EDIfilesave] settings

These settings used by eManifest are located in the [EDIfilesave] section of your TTS50.

[EDIfilesave]309AutoUpdate

Applies to

TMWSuite, TMW eManifest

Description

This setting automates the sending of 309 updates to previously submitted ACE and ACI reports.

Options

  • N (default)
    For 309 updates, you must enter an update type, reason, and Shipment Control Number (SCN).

  • Y
    The system automatically sends a MODIFY amendment message using the primary SCN on the trip, and an amendment code of 03. You are not prompted for an update type, reason, or SCN.

[EDIfilesave]309Data

Applies to

TMWSuite, TMW eManifest

Description

Specifies a path for moving the 309 data to a flat file. When you validate a 309 message set, TMW eManifest creates a default file name of 309_ hhmmss in this folder, where hhmmss is a unique time stamp. Be sure to add a trailing backslash after the path.

Options

  • Blank, that is, no entry (default)
    EDI 309 flat files are created in the C:\EDI\ folder.

  • User-defined path
    EDI 309 flat files are created in the specified folder.

[EDIfilesave]353Data

Applies to

TMWSuite, TMW eManifest

Description

Specifies a path for moving the 353 data to a flat file. When you validate a 353 message set, TMW eManifest creates a default file name of 353_ hhmmss in this folder, where hhmmss is a unique time stamp. Be sure to add a trailing backslash after the path.

Options

  • Blank, that is, no entry (default)
    EDI 353 flat files are created in the C:\EDI\ folder.

  • User-defined path
    EDI 353 flat files are created in the specified folder.

[EDIfilesave]358AutoUpdate

Applies to

TMWSuite, TMW eManifest

Description

This setting automates the sending of 358 updates to previously submitted ACE and ACI reports.

Options

  • N (default)
    For 358 updates, you must enter an update type, reason, and Shipment Control Number (SCN).

  • Y
    The system automatically sends a MODIFY amendment message using the primary SCN on the trip, and an amendment code of 03. You are not prompted for an update type, reason, or SCN.

[EDIfilesave]358Data

Applies to

TMWSuite, TMW eManifest

Description

Specifies a path for moving the 358 data to a flat file. When you validate a 358 message set, TMW eManifest creates a default file name of 358_ hhmmss in this folder, where hhmmss is a unique time stamp. Be sure to add a trailing backslash after the path.

Options

  • Blank, that is, no entry (default)
    EDI 358 flat files are created in the C:\EDI\ folder.

  • User-defined path
    EDI 358 flat files are created in the specified folder.

[EDIfilesave]AceTrailerSealValidationRule

Applies to

TMWSuite, TMW eManifest

Description

Use this setting to set the message validation rule the system will use when a stop’s Trailer Seal reference type and reference number are missing. The setting applies to 358 and 309 reporting documents.

Options

  • Information (default)
    The Batch/Error Log window displays an entry for the purpose of information, only. The system can create reporting documents.

  • Warning
    The Batch/Error Log window displays a warning. The system can still create reporting documents.

  • Error
    The Batch/Error Log window displays an error similar to the following: "Current settings require at least one trailer seal number to be present in order to continue." The system cannot create reporting documents.

[FuelDispatch] settings

These settings used by eManifest are located in the [FuelDispatch] section of your TTS50.

[FuelDispatch]AllowOrderScrollCheckAllStops

Applies to

CRM Right, Fuel Dispatch, Inventory Services, TMW eManifest, TMW Operations

Description

By default, if you use the Company tab of the Order Scroll window to search for a shipper or consignee, the search returns only the first and last stops for orders found.

Use this setting to add a check box on the window if you want users to be able to include all stops for orders with a particular shipper or consignee.

Options

  • N (default)
    Hides the Check All Stops check box from the Order Scroll window.

  • Y
    Displays the Check All Stops check box from the Order Scroll window.

[FuelDispatch]DoColumnChooserDisableIfNotAdmin

Applies to

TMWSuite Add-ins, CRM Right, Fuel Dispatch, Inventory Services, TMW Back Office, TMW eManifest, TMW Operations

Description

If you are a system administrator, you can remove users' ability to use the Field Chooser function for all data grids. This prevents users from adding or removing columns. You can use this INI setting to prevent users who are not system administrators from seeing the Field Chooser.

Options

  • N (default)
    Field Chooser will show on data grids whether the user is a system administrator, supervisor, or user.

  • Y
    Field Chooser will only show on data grids if the user is a system administrator.

Additional Notes

It is recommended that the system administrator also set the ShowResetLayoutForNonSA=N in the [Misc] section of the TTS50.INI. This setting prevents users from resetting a layout back to the factory default.

[Misc] settings

These settings used by eManifest are located in the [Misc] section of your TTS50.

[Misc]CaseSensitivePasswords

Applies to

TMWSuite

Description

This setting controls whether the system treats login passwords as case sensitive.

Note: This setting no longer applies to these applications:

  • TMW Operations, starting with 17.50

  • TMW Back Office, starting with 17.50

  • CRMRight, starting with 17.50

  • Fuel Dispatch, starting with 17.20

  • Inventory Services, starting with 17.20

  • eManifest, starting with 17.50

Starting with these versions, passwords that were created without case sensitivity must always be entered in upper case.

Options

  • OFF (default)
    System stores password as all upper case.

    Notes:

    1. Although the system default is still OFF, TMW has opted to change the value in the installed TTS50 file to ON. If the setting is not present in your INI file, the system default of OFF will apply.

    2. When you use this option, you can log on to TMWSuite by typing your password in mixed case. The system accepts and processes the password as being entered in upper case.

    3. When using a TMW application password to log on to Microsoft SQL Server 2005 and later, you must type your password in upper case. Press the SHIFT key to do this.

    4. If you create a password using this option, but later switch to the ON option, you must type your password in upper case. Use the SHIFT key to do this. This applies to TMWSuite and Microsoft SQL Server 2005 (and later).

  • ON
    System stores the password as it was entered.

    Notes:

    1. When logging on to TMWSuite or Microsoft SQL Server 2005 (and later) using a TMW application password, you must use the case sensitive password.

    2. Passwords created using this option, will not work if either of these occur. If they do, contact your system administrator.

      • The setting is switched to the OFF option.

      • The setting is removed from your TTS50.

Additional Notes

If the system is set up to use Microsoft SQL Server standards for password complexity, passwords must contain at least one letter, one number, and one non-alphanumeric character, such as an exclamation point. The password must not contain your entire account name or display name.

[Misc]DatetimeEditMode

Applies to

TMWSuite, CRM Right, TMW Operations, TMW eManifest

Description

This setting determines where the cursor will be positioned within a date/time field when the TAB key is used to enter the field.

Options

  • 0 (default)
    Highlight the month and day (MMDD).

  • 1
    Place the cursor in the time section of the field.
    Note: Fields with genesis and apocalypse dates are exceptions.

    • In TMWSuite:
      For fields with 12/31/49 and 01/01/50, the system highlights the month and day (MMDD).

    • In TMW Operations, CRM Right, and TMW eManifest
      For fields with 12/31/49 and 01/01/50, the system highlights the entire field (MMDDYY HH:MM).

Additional Notes

  1. In TMW Operations, CRM Right, and TMW eManifest, this setting works in tandem with the [Misc]DateTimeTabInteraction setting to determine tabbing behavior.

  2. Fuel TMS does not support this setting.

[Misc]DateTimeTabInteraction

Applies to

CRM Right, TMW Operations, TMW eManifest

Description

This setting determines tabbing behavior from within a date/time field on a window or in a grid.

Options

  • 0 (default)
    Pressing TAB inside a date/time field will select each part (MM/DD/YY HH:MM) of the date and time, then exit the field.

  • 1
    Pressing TAB within a date/time field will exit the field, regardless of the cursor position.

Additional Notes

  1. In TMW Operations, CRM Right, and TMW eManifest, this setting works in tandem with the DateTimeEditMode setting to determine tabbing behavior.

  2. TMWSuite does not support this setting.

  3. Fuel TMS does not support this setting.

Applies to

TMWSuite, CRM Right, TMW eManifest, TMW Operations, TMW Back Office

Description

This setting identifies the file name of the large bitmap used in the Login dialog box of TMW modules. The bitmap should be located in your TMWSuite executable directory.

To display an alternate image in the Login dialog box, you must make a valid entry in both the [Directories]Bitmaps setting and the [Misc]Logo setting.

Options

  • TMW_D.BMP (default)
    The file name of the TMW logo that displays in the Login dialog box.

  • Logo file name
    Enter the name of the file you want to display in the Login dialog box.

Additional Notes

  1. Image files must be either BMP or JPG file type.

  2. Image dimensions should be 450 pixels wide and 330 pixels high.

  3. If a valid entry is not made in both the Bitmaps setting and the Logo setting:

    • TMWSuite core applications will display a blank pane (no image).

    • CRM Right, TMW Operations, and TMW Back Office will display the default TMWSuite logo.

  4. Fuel TMS does not support this setting.

[Misc]OrderScrollDaysBack

Applies to

TMWSuite: 2000, CRM Right, Fuel Dispatch, Inventory Services, TMW eManifest, TMW Operations

Description

This setting affects the Start From and Delivery From dates on the Scroll Orders window. Enter the number of days prior to today that you want the From dates set back, such 60 or 90.

Options

  • 30 (default)
    Set the From dates to 30 days prior to today’s date.

  • User-defined number of days
    Enter the number of days prior to today that you want the From dates set back.

  • BeginningOfTime
    Set the From dates to 01/01/50.

Additional Notes

In TMWSuite, the [Misc]MaxOrderScrollDays setting specifies the max number of days for which the system will search for orders. If the date range resulting from this setting exceeds the specified limit, the system will behave as defined by the [Misc]MaxOrderScrollExceededActions setting.

[Misc]RemoveScrollExportToExcelMenuOption

Applies to

CRM Right, Fuel Dispatch, Inventory Services, TMW eManifest, TMW Back Office, TMW Operations

Description

When you right-click on retrieved records in a .NET scroll window, a shortcut menu appears. This setting determines whether the Export to Excel command is available in that shortcut menu.

Options

  • N (default)
    Display the Export to Excel command for all users.

    Note: When you have [Misc]RemoveExportToExcelMenuOptionFromAllGrids=Y, this setting is ignored.

  • Y
    Do not display the Export to Excel command for any users, including system administrators and supervisors.

Additional Notes

  1. For Fuel Dispatch and Inventory Services, this setting is functional only if [Misc]UseNewScrolls=Y in your TTS50.

  2. For CRM Right, this setting also affects the Company List and Carrier List retrieval grids.

[Misc]ShowResetLayoutForNonSA

Applies to

TMWSuite Add-ins, CRM Right, Fuel Dispatch, Inventory Services, TMW Back Office, TMW eManifest, TMW Operations

Description

TMW customers apply security to windows and grids by hiding some columns and fields, and by making others read-only. However, by default, any user can switch from a customized window or data grid layout back to the system default by right-clicking on the layout and selecting Reset Layout from the shortcut menu. This can be problematic because the system default has no security applied to it. As a result, users will be able to view or make entries in fields or columns that your company wants to be hidden or read-only.

You can use the ShowResetLayoutForNonSA INI setting to hide the Reset Layout menu selection for users who are not system administrators.

Options

  • Y (default)
    Show the Reset Layout menu option for users who are not system administrators.

  • N
    Do not show the Reset Layout menu option for users who are not system administrators.