Hazmat Routing

If the separate HazMat data add-on module is installed, routing can be generated in North America, Europe and Oceania for various types of hazardous materials and dangerous goods using any PC*Miler route type.

To generate a route for hazardous materials, select a Hazardous Materials route type in the Route Options dialog > Routing Preferences tab for the open route or create/edit a route profile to use for hazmat routing.

Hazardous material routing options for North America include: Other, Corrosive, Explosives, Flammable, Inhalants, and Radioactive. When Europe or Oceania is the selected region, the options are: Other, Explosives, Flammable, and Harmful to Water. (Additional tunnel restrictions categories in Europe – see Table 2 below).

vy3c1EeSuT kfJX3f4kgz9bjZfWzlRU25Q

The Other option should be used for any hazardous material that presents a danger during transportation and is not corrosive, explosive, flammable, inhalant, or radioactive. Common examples include: oxidizers (such as compressed oxygen tanks), combustible liquids (such as diesel fuel), and poisons (such as pesticides).

Table 1: Hazardous Material Route Options and Road Categories

Depending on the Hazmat value you select, the routing algorithm will generate legal and safe routes by avoiding or favoring certain types of roads. The charts below describe the impact on routing based on the hazmat type.

favor = routing will prefer these segments

no change = routing will not be altered in any way

avoid = routing will go around these segments whenever possible

discourage = a lesser degree of avoidance, used when a state or road authority allows hazmat only at certain times of day, with prior notification, by permit, or in limited quantities, and for tunnels not otherwise classified

Hazmat Routing Category Other Corrosive Explosives Flammable Inhalants Radioactive Hazmat Map Legend

None

no change

no change

no change

no change

no change

no change

None

Designated

favor

favor

favor

favor

favor

favor

Desig/Pref/Alt

Prohibited

avoid

avoid

avoid

avoid

avoid

avoid

Prohibited

Restricted

discourage

discourage

discourage

discourage

discourage

discourage

Restricted

Harmful to Water Prohibited (EU only)

no change

no change

no change

no change

no change

no change

Some Cmds Prohib

Explosive Designated

no change

no change

favor

no change

no change

no change

Desig Expl

Inhalant Designated

no change

no change

no change

no change

favor

no change

Desig Inhal

Explosive & Inhalant Designated

no change

no change

favor

no change

favor

no change

Desig/Pref/Alt

Tunnel & Explosive Prohibited

no change

no change

avoid

no change

no change

no change

Prohibited

Tunnel & Explosive and Flammable Prohibited

no change

no change

avoid

avoid

no change

no change

Prohibited

Tunnel & Other, Explosive, Flammable and Inhalant Prohibited

avoid

no change

avoid

avoid

avoid

no change

Prohibited

Tunnel & Other, Corrosive, Explosive, Flammable and Inhalant Prohibited

avoid

avoid

avoid

avoid

avoid

no change

Prohibited

Tunnel & Prohibited

avoid

avoid

avoid

avoid

avoid

avoid

Prohibited

Tunnel & Restricted

discourage

discourage

discourage

discourage

discourage

discourage

Restricted

Tunnel & Large Explosive, Inhalant, and Flammable Prohibited (EU only)

no change

no change

no change

no change

no change

no change

Some Cmds Prohib

Tunnel & Large Explosive and Inhalant Prohibited (EU only)

no change

no change

no change

no change

no change

no change

Some Cmds Prohib

Corrosive, Explosive, Flammable & Radioactive Prohibited

no change

avoid

avoid

avoid

no change

avoid

Some Cmds Prohib

Explosive Restricted

no change

no change

discourage

no change

no change

no change

Restricted

Tunnel & Very Large Explosive Prohibited (EU only)

no change

no change

no change

no change

no change

no change

Some Cmds Prohib

Explosive & Flammable Prohibited (EU only)

no change

no change

avoid

avoid

no change

no change

Some Cmds Prohib

Tunnel & Radioactive Prohibited

no change

no change

no change

no change

no change

avoid

Prohibited

Radioactive Designated

no change

no change

no change

no change

no change

favor

Desig Rad

Radioactive Prohibited, Explosive Restricted

no change

no change

discourage

no change

no change

avoid

Some Cmds Prohib

Radioactive Prohibited

no change

no change

no change

no change

no change

avoid

Some Cmds Prohib

Escort Needed

no change

no change

no change

no change

no change

no change

None

Explosive and Flammable & Harmful to Water Prohibited (EU Only)

no change

no change

avoid

avoid

no change

no change

Some Cmds Prohib

Explosives, Inhalant & Radioactive Designated

no change

no change

favor

no change

favor

favor

Desig/Pref/Alt

Radioactive & Explosive Designated

no change

no change

favor

no change

no change

favor

Desig/Pref/Alt

Radioactive & Explosive Prohibited

no change

no change

avoid

no change

no change

avoid

Prohibited

Radioactive & Explosive Restricted

no change

no change

discourage

no change

no change

discourage

Restricted

Table 2: Additional Hazmat Categories in Europe

For PC*Miler Worldwide and DTOD data users, the hazmat categories below are used in the Europe and Oceania regions.

Hazmat Routing Category EU Harmful to Water None EU Tunnel B, C, D, E EU Tunnel C, D, E EU Tunnel D, E EU Tunnel E

None

no change

no change

no change

no change

no change

no change

Designated

no change

no change

no change

no change

no change

no change

Prohibited

avoid

no change

no change

no change

no change

no change

Restricted

no change

no change

no change

no change

no change

no change

Harmful to Water Prohibited

avoid

no change

no change

no change

no change

no change

Explosive Designated

no change

no change

no change

no change

no change

no change

Inhalant Designated

no change

no change

no change

no change

no change

no change

Explosive & Inhalant Designated

no change

no change

no change

no change

no change

no change

Tunnel & Prohibited

no change

no change

avoid

avoid

avoid

avoid

Tunnel & Restricted

no change

no change

no change

no change

no change

no change

Tunnel & Large Explosive, Inhalant, and Flammable Prohibited

no change

no change

avoid

avoid

avoid

no change

Tunnel & Large Explosive and Inhalant Prohibited

no change

no change

avoid

avoid

no change

no change

Corrosive, Explosive, Flammable & Radioactive Prohibited

no change

no change

no change

no change

no change

no change

Explosive Restricted

no change

no change

no change

no change

no change

no change

Tunnel & Very Large Explosive Prohibited

no change

no change

avoid

no change

no change

no change

Explosive & Flammable Prohibited

no change

no change

no change

no change

no change

no change

Radioactive Designated

no change

no change

no change

no change

no change

no change

Radioactive Prohibited, Explosive Restricted

no change

no change

no change

no change

no change

no change

Radioactive Prohibited

no change

no change

no change

no change

no change

no change

Escort Needed

no change

no change

no change

no change

no change

no change

Explosive and Flammable & Harmful to Water Prohibited

avoid

no change

no change

no change

no change

no change

Explosives, Inhalant & Radioactive Designated

no change

no change

no change

no change

no change

no change

Radioactive & Explosive Designated

no change

no change

no change

no change

no change

no change

Radioactive & Explosive Prohibited

no change

no change

no change

no change

no change

no change

Radioactive & Explosive Restricted

no change

no change

no change

no change

no change

no change