TMT Fleet Maintenance V.2022.1.2 Release Notes
This section contains information on the latest version, including:
-
Enhancements (new or updated features)
-
Resolved issues (application improvements)
Warnings
Important information, please read
-
TMT Client-Server (Delphi) 2019.4.1 or any earlier version cannot be used with TMT Fleet Maintenance 2022.1.2. Do not upgrade unless you are ready to go to TMT Web only.
-
Customers using both Integration Options and Windows Authentication should set up their systems so that User drop-down lists use the WINUSER value, instead of the USERNAME value.
-
This version requires .Net Framework 4.8. See the hardware requirements for more information.
-
Customers who are on versions of TMT Web before 2021.3 may be exposed to a vulnerability documented by one of our third-party software vendors (Telerik). Guidance varies depending on the installed TMT Web version (see below). For information directly from Telerik, please use this xref: https://docs.telerik.com/devtools/aspnet-ajax/knowledge-base/common-allows-javascriptserializer-deserialization
-
2021.3, 2021.3.2, 2021.3.3, 2022.1, and later
These versions use an upgraded Telerik version that has patched the vulnerability. No changes are needed.
-
2019.4
A future service pack will include patched Telerik DLLs. In the meanwhile, remediation is possible via web.config changes.
-
2019.2
-
Remediation possible with web.config changes in this version and higher (2019.2-2021.2.X).
-
-
Before 2019.2:
-
Remediation is not possible with web.config changes. You must upgrade.
-
For Delphi/Web hybrid customers, see 2019.4 section above. For all others, we would suggest you upgrade to the latest version of TMT Web.
-
-
Telerik Vulnerability Remediation
Please refer to this link for detailed steps on patching this vulnerability:
This involves web.config changes, and it can be done without taking an upgrade. However, we strongly encourage you to upgrade to a later version of TMT Web for the greatest level of mitigation.
Before upgrading your production environment, Trimble recommends that you read the hardware requirements and install the latest version in a test environment. If you have questions, please contact your Trimble customer representative. |
Changes to hardware requirements
This version has new SQL Server requirements. You must be using SQL Server 2016 or later to use TMT Web V.2022.1 or later.
For SQL Server 2016, the minimum compatibility mode is 130. TMT Web will also support modes 140 and 150.
There are two files from Microsoft that are required for this version:
-
SQL Server 2016 CLR Types
-
SQL Server 2016 Shared Management Objects
You must download and run both files using these links before upgrading to TMT Web V.2022.1:
-
SQL Server 2016 SP2 feature pack
-
SQL Server 2016 SP3 feature pack
You must not delete the 2008R2 CLR/SMO SQL Server components from any TMT Web environment when installing or upgrading. The installer is still using these components at this time. |
Windows Server and SQL Server upgrades are included in TMT Web software as a service (TMT Web SaaS). For information about upgrading to TMT Web SaaS or other technical questions, contact Dawn Siegel at [email protected].
If you have technical questions, contact TMT Support:
-
Email
-
Phone
800-663-0626. Select option 6, and then option 3.
Windows Server and SQL Server Support
-
Windows Server 2012, 2016, and 2019 support SQL Server 2016.
-
Windows Server 2022 does not support SQL Server 2016.
-
Windows Server 2012, 2016, 2019, and 2022 support SQL Server 2017.
-
Windows Server 2016, 2019, and 2022 support SQL Server 2019.
-
Windows 2012 does not support SQL Server 2019.
Internet Explorer 11 End of Life
Starting June 15, 2022, Microsoft will stop supporting Internet Explorer 11 (IE) for some operating systems. Users affected by the IE end of life can use Microsoft Edge in IE mode. The Edge IE mode supports sites that need IE.
IE is a part of the Windows operating system. As such, Microsoft will provide IE 11 security updates and support for Windows versions on which IE is installed. This will continue as long as Microsoft supports those versions. For more information, see https://docs.microsoft.com/en-us/lifecycle/faq/internet-explorer-microsoft-edge.
The end of IE will affect Interactive Workstation (IWS) users. IWS users can use Edge in IE Mode or consider switching to Trimble Technician Portal (TTP). For details on TTP, see:
You must be logged in to learn.transportation.trimble.com to view the TTP Guides. |
Enhancements
Product wide
-
TMT-315807
The Web installer has these improvements:
-
It works with SQL Server 2016 common language runtime (CLR) types and SQL Server 2016 shared management objects (SMO).
-
It can run the DB Test Connection though the SQL Server 2008R2 CLR Types without errors, even if the server does not have SQL SMO.
-
It only checks the SQL Server 2016 minimum requirement on the SQL Server. It does not check for the requirement on the Web or Application servers.
-
The Install links on the Configuration requirements page let you install the 64-bit SMO and CLR types directly from the installer. If you want to install the 32-bit version, you must do it manually.
-
Masters menu
Customers
-
TMT-315064
The new Customer DOT Number field has been added to the:
-
Customers page, Definition tab
-
Add New Customer pop-up window
-
Unit/Customer on the Fly pop-up window
If you enter a customer DOT number that is already in use, the program shows the warning message "Customer DOT Number number has already been applied to Customer Customer ID."
If the Require Customer DOT Number Application option is set to YES, you must complete the Customer DOT Number field when you create or update customer details. For details, see TMT-315064 in Setup menu > Options > Application Options > Invoicing.
-
Shop Inventory
-
TMT-315274
For details, see TMT-315274 in Masters menu > Parts Catalog.
Vendor Parts
-
TMT-315274
For details, see TMT-315274 in Masters menu > Parts Catalog.
Orders menu
Purchase Order
-
TMT-315245
There is a new Application option: Do Not Allow Misc Lines on Standard POs. It controls whether you can add miscellaneous (MISC) lines to POs. For details, see TMT-315245 in Setup menu > Options > Application Options > Purchasing.
Purchase Order > Vendor Parts on Fly
-
TMT-315274
For details, see TMT-315274 in Masters menu > Parts Catalog.
Repair Order
-
TMT-313046
When you have the Tire Module, you can remove a tire from a unit that does not have a tire configuration.
Repair Order > Vendor Parts on Fly
-
TMT-315274
For details, see TMT-315274 in Masters menu > Parts Catalog.
Setup menu
Options > Application Options > Invoicing
-
There is a new invoicing option: Require Customer DOT Number.
-
If set to NO (default), the customer DOT number is not required when creating or updating customer details.
-
If set to YES, the customer DOT number is required for entry when creating or updating customer details.
This option applies only to the Application level.
-
Options > Application Options > Purchasing
-
There is a new purchasing option: Do Not Allow Misc Lines on Standard POs. It controls whether you can add miscellaneous lines on POs.
-
If set to NO (default), you can have miscellaneous lines on standard POs.
-
The Misc option is available in the Line Type drop-down list in the Create New Line pop-up window.
-
Misc shows up as a column in the Order Totals grid. The value matches the total value of the miscellaneous lines, if any.
-
You can edit miscellaneous line rows in the Receive Purchase Order pop-up window.
-
Misc shows up in the summary in the Receive Purchase Order pop-up window.
-
-
If set to YES, you cannot have miscellaneous lines on standard POs.
-
The Misc option is not available in the Line Type drop-down list in the Create New Line pop-up window.
-
There is a Misc column in the Order Totals grid, but the total is always $0.00.
-
You cannot edit miscellaneous line rows in the Receive Purchase Order pop-up window
-
Misc shows up in the summary in the Receive Purchase Order pop-up window, but the total is always $0.00.
-
This option applies only to the Application level.
-
Options > Integration Options > TMT ServiceConnect
-
TMT-315971
The Ignore Invalid Meters and Ignore Invalid Trailer Meters options have been removed. The program now handles invalid meters differently. These options are no longer needed.
If the program receives an invalid meter reading from the integration, it will leave the RO header meter field blank. You can correct the blank meter field, if required, when you save the RO header.
-
TMT-315972
If the TravelCenters of America or ServiceConnect integrations passes a meter reading to TMT, and the meter is mapped to a TMT value, TMT uses the mapped value.
If the integrations pass an unmapped meter reading, TMT will try to use the default value. If the TMT value is set to PRIMARY, then the program selects the primary meter on the unit. If the unit has no primary meter, then TMT ignores the reading.
If the selected meter is not set up on the unit, the program will ignore the reading.
Resolved issues
Activities Menu
Accounting > Accounting > IES
-
TMT-315998
Now, when you click Search or refresh the page, exported orders are removed from the GL, AR, and AP tabs.
Masters menu
Shop Inventory
-
TMT-314200
The Cost History tab updates correctly when you add, edit, or delete any part in a repair invoice.
-
TMT-315233
When you return a tire to inventory from the Tire Review page, the program applies the correct item value. It is based on the accounting method in use. The Shop Inventory page Cost History tab shows the correct item price.
-
TMT-316071
The part value in the Shop Inventory’s Costs and Cost History tabs match the part value added to the RO. It matches the cost coming into inventory from the RO line.
-
TMT-316821
Fixed the issue of the negative quantity returned to shop inventory via fuel data import is populated with zero dollars ($0.00).
Orders menu
Fuel Tickets Listing
-
TMT-315473
For details, see TMT-315743 in Activities menu > Fuel Data Import.
-
TMT-315495
You can create consecutive fuel tickets without getting errors.
-
TMT-316099
Fuel tickets created from edited exceptions are added to the correct batch.
Purchase Order
-
Two users can edit the same VRO without causing line errors between the VRO and the PO. For example, assume Users A and B are working on the same VRO. User A deletes a line. User B makes a change and tries to save the VRO. The program alerts User B that someone has made a line change, and they must refresh the VRO before saving.
-
TMT-315549
You can edit these fields on a closed standard PO:
-
Check Date
-
Check Number
-
Amount Paid
-
Packing Slip Number
-
Invoice Comments
-
Repair Order
-
TMT-314973
The Job Code field is not required when you:
-
Have the Default Existing Job Code & Allow Assignment W/O Job Code Application option set to YES
-
Create an RO section
-
Enter a component code
-
Assign a mechanic
To open the Application option, go to Menu > Setup > Options > Application Options > Repairs > Job Codes.
-
-
TMT-315446
For details, see TMT-315446 in Orders menu > Purchase Orders.
-
TMT-315563
The program saves meter readings when you create an RO from an RO template that has a unit with Auto Load Meter set to YES. On the RO header, the Unit and Customer fields are inactive.
Trimble Technician Portal
-
TMT-315676
TTP now uses the same user lock out security as TMT Web. If you enter your password incorrectly five times, TTP locks you out. If you try to sign in again before the lock out time is over, TTP shows an error message. It states, "User Account Locked for number more minutes. If you need assistance, contact a system administrator."